The Kidde KN-COSM-BA Combination Carbon Monoxide & Fume Alarm provides two important prophylactic devices in a single unit. This alarm includes a voice alarm organisation that announces "Fire, Carbon Monoxide, Low Battery and Smart HushTM Activation." The voice alarm eliminates any confusion and conspicuously warns you and your family of a smoke or carbon monoxide danger, or if your battery is in need of replacement. This technologically advanced combination alarm is battery operated protecting you and your family fifty-fifty during a power outage when many incidences occur.

The KN-COSM-BA is an easy to install alert that is suitable for all living areas and has a 7-year life and a 7-year limited warranty. This alarm uses ionization sensing technology. Leading authorities recommend that both ionization and photoelectric smoke alarms exist installed to assist insure maximum detection of the various types of fires that can occur inside the home. Ionization sensing alarms may discover invisible burn down particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may notice visible burn down particles (associated with tedious smoldering fires) sooner than ionization alarms.

Alert Warnings

Fire:

The red LED will flash and be accompanied by 3 long alarm beeps followed by a verbal warning message "FIRE!". The alert pattern volition echo until smoke is eliminated.

Carbon Monoxide:

Four brusk alarm beeps followed by a exact warning "Warning! CARBON MONOXIDE!" This continues until the unit is reset or the CO is eliminated.

Depression Battery:

If any form of battery failure is detected the red LED light will flash and the unit volition "chirp" once every sixty seconds for at least 7 days. The "Depression BATTERY" voice occurs one time every 15 minutes. The greenish LED volition also be flashing twice per second.

Vocalisation Hush Indication:

"HUSH MODE ACTIVATED" and "HUSH MODE CANCELLED" phonation announcement.

Superlative Level Retention:

If the alarm had detected a CO level of 100ppm or higher, the unit will announce "CARBON MONOXIDE PREVIOUSLY DETECTED" to warn of the CO incident, when the Test/ Reset button is pressed.

Function Number (Ordering Number): 900-0102

  • Phonation Alarm – Announces the hazard type detected thereby helping to speed upwards the correct reaction to the hazard detected. Alarm announces "Burn down!" when a smoke or fire hazard is detected and announces "Warning Carbon Monoxide" when a CO hazard is detected.

  • Combined Carbon Monoxide and Fume Alarm – A unmarried unit of measurement can exist installed where previously, 2 were needed. Reduces installation fourth dimension and helps to go on home décor attractive.

  • Examination/Reset Button – Tests alarm circuitry and triggers the voice announcement.

  • LEDs – Flashing green for normal operation and flashing crimson for warning condition.

  • Low Bombardment Warning – The unit warns of a depression bombardment condition past announcing "low battery" and by initiating an alarm chirp and activating a flashing red LED.

  • Bombardment Powered – Provides protection even during power outages when many burn down and carbon monoxide incidents occur.

  • Bombardment Safeguard – The bombardment door will non close unless the batteries are properly installed.

  • Hush® Feature – Temporarily silences nuisance alarms.

  • Ionization Fume Alarm Sensor

Technical Specifications

Model: KN-COSM-BA
Ability Source: 2 AA Battery
Sensor: Smoke: Ionization, CO: Electrochemical
Audio Alarm: 85dB at 10ft
Temperature Range: 40˚F (4.iv˚C) to 100˚F (37.8˚C)
Humidity Range: ten%-95% relative humidity non-condensing
Size: 5.6" in bore 10 one.8" depth
Weight: 13oz
Interconnects: No

Architectural and Applied science Specifications

The combination smoke and carbon monoxide alarm shall exist Kidde Model Number KN-COSM-BA (part number 900-0102A) or approved equal. Information technology shall be powered past 2 AA batteries. The unit shall incorporate an ionization smoke sensor with nominal sensitivity of 0.97 %/ft. The CO sensor shall be of a fuel cell design and provide accurateness of +/-20% + 15ppm. The temperature operating range shall be between 40°F and 100°F (4°C and 38°C) and the humidity operating range shall exist 10% - 95% relative humidity, non-condensing. The combination warning can be installed on the surface of any wall or ceiling post-obit the UL/NFPA/Manufacturer's recommended placement guidelines. The alarm shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling. The warning shall include a test button that will electronically simulate the presence of smoke and CO and cause the unit to go into both modes of alarm. This sequence tests the unit'south electronics to ensure proper operation. The CO sensor will not warning to levels of CO below 30 ppm and will alarm in the post-obit fourth dimension range when exposed to the corresponding levels of CO. 70 ppm CO Concentration 60 – 240 minutes 150 ppm CO Concentration 10 – 50 minutes 400 ppm CO Concentration 4 – 15 minutes The combination alarm shall have two methods of warning for danger: a piezoelectric horn that is rated at 85 decibels at 10 feet and a voice warning that identifies the danger. For a CO incident, the horn will sound in the repetitive style -- four (4) fast beeps, a brusque pause, iv (4) fast beeps, a brusk pause. In between, the unit will announce "Warning Carbon Monoxide!". In a Smoke incident, the horn will sound in the repetitive way -- three (three) beeps, a break, 3 (3) beeps, a pause. In betwixt, the unit volition denote "Fire!" The unit shall too point a low bombardment alarm utilizing each of the post-obit methods: a brief alert chirp, the voice annunciation of "Depression Battery!" and the blood-red LED will flash once per infinitesimal. The unit shall incorporate 2 LED's. A green LED will wink every 60 seconds in standby status. A red LED will flash during fume or CO alarm, and in error mode. The unit shall at a minimum run into the requirements of UL 2034, UL217, NFPA72, (affiliate 11 2002 edition) The Land of California Burn down Marshall, NFPA101 (One and 2 family dwellings) Federal Housing Authority (FHA), Housing and Urban Development (HUD). Information technology shall too include a 7-year manufacturer's express warranty.

KN-COSM-BA-Diagram

forsternower1951.blogspot.com

Source: https://www.kidde.com/home-safety/en/us/products/fire-safety/combination-smoke-co-alarms/kn-cosm-ba/

0 Response to "Kiddie Recall Kn Cosm 1b Replacement Fire and Carbon Monoxide Review"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel